Translucent roofing sheet Composite/FRP is a fiber-reinforced plastic sheet used to bring natural light into roofs or walls. Hưng Thịnh Phát manufactures and supplies the lines Maxlight, Maxcool, Natalight, flat sheets and Kliplok sheets; the final specifications are confirmed according to the roof profile, color, thickness, length, and the profile of each order.
This page does not use a luminous number, lifespan, or warranty for all products. Those indicators vary according to configuration and are only valid when stated on the quotation, technical sheet, or warranty conditions of the specific product.
What is the Composite roofing skylight panel?
Within the range of products on this page, FRP is a fiber-reinforced polymer material; “Composite” is a broader term for composite materials. The specific composition of the resin system, reinforcement layer, surface layer, and additives must be referenced in the documentation of each product line. Composite/FRP sheets should not be assumed to be Polycarbonate sheets.
Polycarbonate (PC) and Composite/FRP are two different groups of materials. Therefore, the specifications of PC sheets such as material label, co-extrusion technology, impact resistance, or surface coating cannot be used in place of FRP sheet specifications if notthere is documentation to confirm.
Product table of skylight roofing sheets
The table below uses the specifications published on each product page. “Confirm” means that a common number is not used for all orders; the customer needs to receive a technical datasheet or written confirmation before purchasing.
| Products | Material | Profile | Size | Thickness | Light transmission | Application | Warranty | CTA |
|---|---|---|---|---|---|---|---|---|
| 12-Wave FRP Translucent Roofing Sheet, 90cm Wide Maxlight FRP Translucent Roofing Sheets |
Composite/FRP | 12 circular waves | 90cm | 1–3mm; confirm when ordering | According to the color sample and technical sheet | Roof, factory walls, and greenhouses | According to the approved configuration's warranty conditions | Request a quote |
| Plastic corrugated iron Composite 9 square waves, size 107cm Maxlight FRP Translucent Roofing Sheets |
Composite/FRP | 9 square waves | 107cm | Confirmation according to the quotation | According to the color sample and technical sheet | Roof, wall with 9-square-wave profile | According to the approved configuration's warranty conditions | Request a quote |
| Natalight light roofing sheet, 12 round waves, 90cm size Light roofing sheet Natalight |
According to the Natalight file | 12 circular waves | 90cm | 0.6–3.0mm; confirm when ordering | According to the color sample and technical sheet | Roof and wall with 12-round-wave profile | According to the approved configuration's warranty conditions | Request a quote |
| Natalight 9 square wave fiber roofing sheet, size 107cm Light roofing sheet Natalight |
According to the Natalight file | 9 square waves | 107cm | 0.4–3.0mm; confirm when ordering | According to the color sample and technical sheet | Roof and wall with 9-square-wave profile | According to the approved configuration's warranty conditions | Request a quote |
| Cooling plastic sheet Composite 9 square waves, 107cm size Light roofing sheet Maxcool |
According to technical sheet Maxcool | 9 square waves | 107cm | 0.4–3.0mm; confirm when ordering | According to the color sample and technical sheet | Roof and walls require square profile | According to the approved configuration's warranty conditions | Request a quote |
| Plastic cooling sheet Composite 12 round waves, 90cm size Light roofing sheet Maxcool |
According to technical sheet Maxcool | 12 circular waves | 90cm | 0.4–3.0mm; confirm when ordering | According to the color sample and technical sheet | The roof has a compatible round profile | According to the approved configuration's warranty conditions | Request a quote |
| Maxlight flat light roofing sheet, size 100cm Flat roofing sheet Maxlight |
According to technical sheet Maxlight | Flat | 100cm | 0.4–3.0mm; confirm when ordering | According to the color sample and technical sheet | Canopy, skylight, and walls | According to the approved configuration's warranty conditions | Request a quote |
| Maxlight flat light roofing sheet, size 120cm Flat roofing sheet Maxlight |
According to technical sheet Maxlight | Flat | 120cm | Confirmation according to design | According to the color sample and technical sheet | Wide module canopy and walls | According to the approved configuration's warranty conditions | Request a quote |
| Industrial corrugated iron Kliplok 4 waves 95cm Industrial light roofing panels |
According to order technical sheet | Kliplok 4 waves | 95cm | Confirmation according to drawings or samples | According to the color sample and technical sheet | Industrial roof with compatible profile | According to the approved configuration's warranty conditions | Request a quote |
| Cooling flat roofing sheet Maxcool size 100cm Flat roofing sheet Maxcool |
Confirmation according to technical sheet | Flat, solid | 100cm | Confirmation according to order | According to the color sample and technical sheet | Canopy, walls, and panels | According to the approved configuration's warranty conditions | Request a quote |
| Cooling flat roofing sheet Maxcool size 120cm Flat roofing sheet Maxcool |
Confirmation according to technical sheet | Flat, solid | 120cm | Confirmation according to order | According to the color sample and technical sheet | Canopy, walls, and panels | According to the approved configuration's warranty conditions | Request a quote |
Choose product line and profile
Maxlight and Natalight
Maxlight and Natalight There are wave pattern options being published. When roofing alternately with metal sheets, it is necessary to check the wave pitch, wave height, total width, useful width, and overlap edge; the names '9 waves' or '12 waves' are not enough to conclude that the two sheets match.
Maxcool, flat panels and industrial panels
Maxcool waveforms, Flat sheet Maxlight, Maxcool flat plate and industrial skylight panel Kliplok Serve different requirements. For flat panels Maxcool, the specific material needs to be confirmed on the technical data sheet instead of being inferred from the brand name.sale.
Which specifications must be finalized before orderinggoods?
- Material: FRP/Composite, PC or other configurations must be specified; do not use two names interchangeably.
- Profile: the number of waves, the wavelength, the wave height, the shape of the crest of the wave, the dimension of the overlap of the eyelids, and the useful gauge.
- Thickness: Choose by profile, support span, wind load, maintenance travel conditions, and data of the right product.
- Length: According to the roof plan, vertical seam overlap, production capability, transportation, and lifting the panels onto the roof.
- Color and light transmission: Confirm according to color sample and technical sheet; do not infer by eye from screen images.
- UV, chemical and fire: Specify the building requirements and only accept claims associated with the test documentation of the correct configuration.
- Warranty: check the deadlines, installation conditions, exclusion environments, documents to be kept, and how to handle complaints.
Select panels based on project application
| Application | Points to check | Related content |
|---|---|---|
| Workshops, warehouses | Illumination, distribution of light strips, profile, wind load, leak prevention and maintenance | How to choose for the factory |
| Factory with chemicals or corrosive | Chemical name, concentration, temperature, exposure time, resin system, and accessories | Chemical evaluation process |
| Metal tile roof | Measure actual profile, overlap dimensions, screws, washers, sealing, and expansion joints | Interlayer Installation Instructions |
| Greenhouses and canopies | Light, heat, ventilation, condensation objectives, panel shape, and supporting frame | Flat plate or formwave |
| Kliplok Industrial Roof | Cross-section drawings, linkage mechanisms, useful width, and construction sequence | 4-wave Kliplok sheet |
How is the price of transparent roofing sheets Composite calculated?
There is no single correct price for every configuration. The quotation depends on the confirmed material, profile, thickness, color, length, quantity, accessories, delivery location, and documentation requirements. To make a proper comparison, it is necessary to match the same effective width, thickness, and delivery scope; not just compare prices per linear meter.
View how to prepare estimates for skylight roofing Composite, then send drawings or roof cross-section photos via the page Request a Quote.
Composite/FRP, Polycarbonate and glass, how are they different?
| Criteria | Composite/FRP | Polycarbonate | Dear |
|---|---|---|---|
| Material Nature | Fiber-reinforced polymer according to product configuration | PC Thermoplastics | Inorganic material; glass configuration must be determined separately |
| Roof profile | Can be produced in corrugated or flat form according to the product line | Available in flat, hollow, or profile forms depending on the manufacturer | Depends on frame system and connection solution |
| Performance parameters | Use the technical datasheet of the correct resin system, reinforcement layer, and surface | Use the datasheet of the correct type of PC and surface layer | Use profiles corresponding to the correct type of glass, thickness, and treatment |
| How to choose | According to environment, profile, load, light, and test file | According to light, heat, expansion, load, and surface profile | According to glass safety, load, frame, temperature, and maintenance |
Read detailed analysis at FRP/Composite and Polycarbonate are different when making skylightsThe words "durable", "UV-resistant", "chemical-resistant", or "fire-resistant" should only be used with conditions and the source of the correct product.
Construction, purlin spacing and leak prevention
- Re-measure roof profiles and confirm overlapping surfaces before production.
- The design or construction unit determines the support spacing according to the load, allowable deflection, and the data of the specific panel; do not use a fixed spacing for all thicknesses.
- Use suitable screws, dragons and sealing materials; arrange the holes and slots according to the instructions so as not to lock the expansion.
- Do not step directly on the skylight panel. There must be a working platform, fall protection equipment, and measures for working at height.
- Acceptance of the overlapping direction, screw position, flatness, sealing point and drainage flow before handover.
Related instructions: how to measure wave pitch and effective width, How to choose the thickness, diagnose yellowing, brittleness, or leakage.
Data required from the manufacturerexport
Hưng Thịnh Phát has a factory in Long An and supplies products according to confirmed specifications. Before signing an order, customers should request the documentation corresponding toRisk level of the construction:
- Quotations or confirmation slips must correctly state the material name, brand, profile, width, thickness, length, color, and quantity.
- Cross-section drawing or sample reference for the existing roof.
- Technical data sheets, test results, or certifications when the contract requires specifications for light transmission, UV, mechanical properties, chemical resistance, or fire.
- Written warranty conditions for the correct configuration, including construction and maintenance requirements.
- Photos, QC records, or approval samples according to project agreement.
Related technical instructions
How Much Do FRP Translucent Roofing Sheets Cost? A Cost Formula
The estimation formula for translucent roofing sheets Composite depends on profile, thickness, size, quantity, accessories, and transportation; do not use prices not approved by the factory.
FRP/Composite vs Polycarbonate Rooflights: What Is Different?
Compare FRP/Composite and Polycarbonate according to roof profile, light, impact, expansion, chemicals, fire, and technical documents to be checked.
How Thick Should FRP Rooflight Sheets Be for a Factory?
Guidelines for selecting the thickness of Composite roofing sheets according to profile, purlin span, wind load, connections, and test data of the correct product.
How to Measure Corrugation Pitch, Depth and Effective Cover Width
Instructions for measuring skylight sheet profiles before installation: wavelength, height, total width, usable width, overlap edge, and field measurement form.
Installing FRP Rooflights Between Metal Roof Sheets
Technical instructions for installing skylight sheets Composite mixed with metal sheets: profile joints, overlaps, screws, expansion holes, leak prevention, and acceptance.
How Much Rooflight Area Does an Industrial Roof Need?
How to calculate the area ratio of translucent panels and the design process according to illuminance, distribution, glare, heat, fire, and maintenance capability.
Selecting Rooflights for Chemical and Corrosive Factories
Procedure to select skylight panels for chemical environments according to agents, concentration, temperature, resin system, accessories, fire, and compatibility documents.
Yellow, Brittle or Leaking FRP Rooflights: Causes and Repairs
Diagnosis tree for skylight panels that are yellowed, brittle, cracked, or leaky; methods to check UV, screws, overlapping edges, profiles, and decide whether to repair or replace.
Frequently asked questions
Is Composite skylight roofing the same as Polycarbonate?
No. Composite/FRP and Polycarbonate are two different material groups. Check the technical sheet of the actual product rather than guessing based on the trade name or old content.
What is the light transmission?
Depends on configuration, color, thickness, and surface condition. Hưng Thịnh Phát needs to be confirmed with samples and technical datasheets for specific products; this page does not publish a general rate for the entire catalog.
Is the sheet UV-resistant, chemical-resistant, or fire-resistant?
Only conclude when there is a corresponding configuration and documentation. It is necessary to clearly state the agent, exposure conditions, and project testing requirements before selection.
Lifespan and warranty duration?
A common reference point should not be used. Actual lifespan depends on materials, UV, environment, load, installation, and maintenance; the warranty period must be read on the order documentation.
What needs to be sent to receive a quote?
Send location, application, photos or profile drawings, effective width, length, expected thickness, color, quantity, and special technical requirements. If there is not enough data, the technical department will indicate the content that needs confirmation.
Send profile, dimensions, quantity, and usage environment to receive a factory quotation.